| F.A.Q |
 |
-
No lights on the display
- Check if the unit is plugged in and if you have power in the plug
- Check if GFCF cable is triggered Check if the ON/OFF switch is ON
- Open the door and check is the small cup under the hot chocolate canister is full of water and if there is water on the drip tray
-
-
The coffee is very weak
- Make sure that there is coffee inside the two canisters
- Make sure that the canisters are in place
- Make sure that no ingredient motor is defective or that a part is not broken inside that canister
-
-
I am getting half a cup of coffee
- Make sure there is no obstruction at the entrance for the whipping chamber
- Check if tubes are not folded
- Make sure valves are not obstructed by calcium or solubles.
-
Low Water Level
- Make sure the inlet valve is connected properly and not leaking
- Check Water Filter – a dirty filter will restrict water flow
- Ensure that the water is not turned off in another part of the building
-
Brewer Error
- This message appears when there is a malfunction with the brew group
- Examine the brew group – remove and rinse if coffee has backed up
- If there is no evident issue with the brew group, turn the machine off, then on
-
Overflow
- Check if there is water on the drip tray or in the overflow cup
- If it’s a Quad, open the side of Vanilla door
- If it’s an Avalon Petite, check behind the waste bucket inside the unit
|
|
|
|
|
|
|
|
|